Compact Converter - IndraDrive Cs HCS02
The IndraDrive C (HCS02) converters cover the middle kW range of the power range. They come with a control unit slot that has various interfaces for connecting to the automation environment, for encoder systems, safety technology, and additional digital and analog signals, etc.
One nameplate photo is enough to start a quote request. You do not need to know the model name.
Features
General data
Type | HCS02.1E-W0012 | HCS02.1E-W0028 | HCS02.1E-W0054 | HCS02.1E-W0070 |
|---|---|---|---|---|
Protection type overall | IP20 | |||
EMC (electro-magnetic compatibility) | EN 61800-3 | |||
Type of cooling | Forced ventilation |
Performance data
Type | HCS02.1E-W0012 | HCS02.1E-W0028 | HCS02.1E-W0054 | HCS02.1E-W0070 | |
|---|---|---|---|---|---|
Continuous current | A | 4.5 | 12 | 20.6 | 28 |
Maximum current | A | 11.5 | 28.3 | 54 | 70.8 |
Motor nominal capacity, typical | kW | 1.5 | 4 | 7.5 | 11 |
Mains connection voltage | 1 AC | 200 ... 250 V | |||
3 AC | 200 ... 500 V | ||||
Tolerance | % | ± 10 - | ± 10 - | ± 10 - | ± 10 - |
Frequency | 50 ... 60 Hz | 50 ... 60 Hz | 50 ... 60 Hz | 50 ... 60 Hz | |
Frequency tolerance | Hz | ± 2 | ± 2 | ± 2 | ± 2 |
Continuous current mains input | A | 6 | 13 | 20 | 30 |
Power dependency from the supply voltage | ULN < 400 V | 1% power reduction per 4 V | |||
ULN > 400 V | 1 % power gain per 5 V | ||||
Network contactor | External |
Intermediate circuit
Type | HCS02.1E-W0012 | HCS02.1E-W0028 | HCS02.1E-W0054 | HCS02.1E-W0070 | ||
|---|---|---|---|---|---|---|
Continuous power with choke | kW | 2.1 | 5.1 | 10 | 14 | |
Max. power with choke | kW | 5 | 10 | 16 | 19 | |
Continuous power without choke | kW | 2.1 | 5.1 | 7 | 9 | |
Max. power without choke | kW | 5 | 8 | 12 | 14 | |
Switching frequency/max. output frequency | 4 kHz | 0 ... 400 Hz | 0 ... 400 Hz | 0 ... 400 Hz | 0 ... 400 Hz | |
8 kHz | 0 ... 800 Hz | 0 ... 800 Hz | 0 ... 800 Hz | 0 ... 800 Hz | ||
12 kHz | 0 ... 1200 Hz | 0 ... 1200 Hz | 0 ... 1200 Hz | 0 ... 1200 Hz | ||
16 kHz | 0 ... 1600 Hz | 0 ... 1600 Hz | 0 ... 1600 Hz | 0 ... 1600 Hz | ||
Output voltage | 3 x AC 0 ... Mains connection voltage V | |||||
Intermediate circuit capacity | mF | 0.135 | 0.27 | 0.54 | 0.675 | |
Intermediate circuit voltage | Mains connection voltage x 1.41 V DC | |||||
Ability to combine converter/inverter | - | ● | ● | ● |
Brake chopper/resistor
Type | HCS02.1E-W0012 | HCS02.1E-W0028 | HCS02.1E-W0054 | HCS02.1E-W0070 | |
|---|---|---|---|---|---|
Brake resistor | Internal | Internal/external | |||
Brake chopper | Internal | ||||
Braking energy consumption | kWs | 1 | 5 | 9 | 13 |
Continuous braking power | kW | 0.05 | 0.15 | 0.35 | 0.5 |
Maximum braking power | kW | 4 | 10 | 18 | 25 |
Control voltage
Type | HCS02.1E-W0012 | HCS02.1E-W0028 | HCS02.1E-W0054 | HCS02.1E-W0070 | |
|---|---|---|---|---|---|
Power consumption without control unit and motor brake | W | 12 | 14 | 23 | 23 |
Legend | |
|---|---|
● | Standard |
○ | Option |
▼ | In preparation |
Applications
- 1.5 kW ... 11 kW power range
- 12 A ... 70 A maximum current
- 200 V ... 500 V direct power supply
- 2.5x overload capacity
- Compact design for single-axis applications