Modular converter - IndraDrive M HMV02 - supply device
The HMV02 supply unit generates a DC bus voltage from the supply voltage. It is available in a rectifier/regeneration variant. This means it can also feed regenerative energy back into the supply network, keeping the DC bus voltage at a constant level regardless of supply voltage. The network contactor, braking transistor or brake resistor are integrated. Air cooling is the only type of cooling available.
One nameplate photo is enough to start a quote request. You do not need to know the model name.
Features
General data
Type | HMV02.1R-W0015 | |
|---|---|---|
EMC (electro-magnetic compatibility) | EN 61800-3 | |
Type of cooling | Forced ventilation |
Performance data
Type | HMV02.1R-W0015 | ||
|---|---|---|---|
Input voltage | 3 x AC 380 ... 480 V | ||
Tolerance | % | ± 10 - | |
Frequency | 50 ... 60 Hz | ||
Frequency tolerance | Hz | ± 2 | |
Continuous current mains input | A | 23 | |
Power dependency from the supply voltage | ULN < 400 V | 1% power reduction per 4 V | |
ULN > 400 V | No power gain |
Intermediate circuit
Type | HMV02.1R-W0015 | |
|---|---|---|
Continuous power with choke | kW | 15 |
Max. power with choke | kW | 30 |
Output voltage | 750 V DC | |
Intermediate circuit capacity | mF | 0.705 |
Brake chopper/resistor
Type | HMV02.1R-W0015 | |
|---|---|---|
Braking energy consumption | kWs | 40 |
Continuous braking power | kW | 0.3 |
Maximum braking power | kW | 33 |
Control voltage
Type | HMV02.1R-W0015 | |
|---|---|---|
Control voltage, external | 24 V ± 5 % - | |
Power consumption without control unit and motor brake | W | 27 |
Applications
- 15 kW power
- 380 V ... 480 V mains connection voltage
- Protection type IP20
- Rectifier and regeneration functions