Modular converter - IndraDrive M HMS02 - single-axis inverter
The HMS02 single-axis inverters are powered by direct current and use it to generate a controlled AC output voltage of variable amplitude and frequency for operating a motor. They come with a control unit slot that has various interfaces for connecting to the automation environment, for encoder systems, safety technology, and additional digital and analog signals, etc. The firmware in the control unit controls the motor inverter and offers extensive additional functions. For multi-axis applications, the inverters are powered by the DC bus from the HMV02 supply unit. It is also possible to power the inverters from the DC bus of an HCS converter for smaller axis packages and with an appropriate power reserve in the HCS02.
One nameplate photo is enough to start a quote request. You do not need to know the model name.
Features
General data
Type | HMS02.1N-W0028 | HMS02.1N-W0054 |
|---|---|---|
EMC (electro-magnetic compatibility) | EN 61800-3 | |
Type of cooling | Forced ventilation |
Performance data
Type | HMS02.1N-W0028 | HMS02.1N-W0054 | |
|---|---|---|---|
Input voltage | 254 ... 750 V DC | ||
Continuous current | A | 13.82 | 25 |
Maximum current | A | 28.3 | 54 |
Motor nominal capacity, typical | kW | 0 | 0 |
Intermediate circuit
Type | HMS02.1N-W0028 | HMS02.1N-W0054 | ||
|---|---|---|---|---|
Switching frequency/max. output frequency | 4 kHz | 0 ... 400 Hz | 0 ... 400 Hz | |
8 kHz | 0 ... 800 Hz | 0 ... 800 Hz | ||
12 kHz | - | 0 ... 1,200 Hz | ||
16 kHz | - | 0 ... 1,600 Hz | ||
Output voltage | 3 x AC 0 ... 500 V | |||
Intermediate circuit capacity | mF | 0.135 | 0.27 | |
Intermediate circuit voltage | 254 ... 750 V DC |
Control voltage
Type | HMS02.1N-W0028 | HMS02.1N-W0054 | |
|---|---|---|---|
Power consumption without control unit and motor brake | W | 13 | 17 |
Applications
- 5.5 kW ... 11 kW power range
- 13.8 A ... 25 A continuous current
- 28 A ... 54 A maximum current
- 540 V ... 750 V DC line voltage
- Protection type IP20