General data

Type

HCS01.1E-W0003-A-02HCS01.1E-W0006-A-02HCS01.1E-W0009-A-02HCS01.1E-W0013-A-02HCS01.1E-W0018-A-02HCS01.1E-W0005-A-03HCS01.1E-W0008-A-03HCS01.1E-W0018-A-03HCS01.1E-W0028-A-03HCS01.1E-W0054-A-03

Protection type overall

IP20

Degree of contamination

2

Type of cooling

UnventilatedForced ventilation

Performance data

Type

HCS01.1E-W0003-A-02HCS01.1E-W0006-A-02HCS01.1E-W0009-A-02HCS01.1E-W0013-A-02HCS01.1E-W0018-A-02HCS01.1E-W0005-A-03HCS01.1E-W0008-A-03HCS01.1E-W0018-A-03HCS01.1E-W0028-A-03HCS01.1E-W0054-A-03

Continuous current

A

1.42.434.4722.77.611.5221

Maximum current

A

3.369131858182854

Mains connection voltage

1 AC 1)

1 x AC 110 ...230 V-

3 AC

3 x AC 110 ... 230 V3 x AC 200 ... 500 V

Tolerance

%

± 10
-
± 10
-
± 10
-
± 10
-
± 10
-
± 10
-
± 10
-
± 10
-
± 10
-
± 10
-

Frequency

50 ... 60 Hz50 ... 60 Hz50 ... 60 Hz50 ... 60 Hz50 ... 60 Hz50 ... 60 Hz50 ... 60 Hz50 ... 60 Hz50 ... 60 Hz50 ... 60 Hz

Frequency tolerance

Hz

± 2± 2± 2± 2± 2± 2± 2± 2± 2± 2

Continuous current mains input

A

0.61.22.34.59.61.52.551028

Power dependency from the supply voltage

ULN < 400 V

1% power reduction per 4 V

ULN > 400 V

No power increase
1)Single-phase operation possible, derating for HCS01.1E-W0013-A-02 and -W0018-A-02

Intermediate circuit

Type

HCS01.1E-W0003-A-02HCS01.1E-W0006-A-02HCS01.1E-W0009-A-02HCS01.1E-W0013-A-02HCS01.1E-W0018-A-02HCS01.1E-W0005-A-03HCS01.1E-W0008-A-03HCS01.1E-W0018-A-03HCS01.1E-W0028-A-03HCS01.1E-W0054-A-03

Continuous power with choke

kW

--------414

Max. power with choke

kW

--------9.719

Continuous power without choke

kW

0.150.250.460.81.80.460.861.72.69

Max. power without choke

kW

0.450.751.382.44.81.382.585.16.214

Switching frequency/max. output frequency

4 kHz

0 ... 400 Hz0 ... 400 Hz0 ... 400 Hz0 ... 400 Hz0 ... 400 Hz0 ... 400 Hz0 ... 400 Hz0 ... 400 Hz0 ... 400 Hz0 ... 400 Hz

8 kHz

0 ... 800 Hz0 ... 800 Hz0 ... 800 Hz0 ... 800 Hz0 ... 800 Hz0 ... 800 Hz0 ... 800 Hz0 ... 800 Hz0 ... 800 Hz0 ... 800 Hz

12 kHz

0 ... 1200 Hz0 ... 1200 Hz0 ... 1200 Hz0 ... 1200 Hz0 ... 1200 Hz0 ... 1200 Hz0 ... 1200 Hz0 ... 1200 Hz0 ... 1200 Hz0 ... 1200 Hz

16 kHz

0 ... 1600 Hz0 ... 1600 Hz0 ... 1600 Hz0 ... 1600 Hz0 ... 1600 Hz0 ... 1600 Hz0 ... 1600 Hz0 ... 1600 Hz0 ... 1600 Hz-

Output voltage

3 x AC 0 ... 230 V3 x AC 0 ... 500 V

Intermediate circuit capacity

mF

0.440.440.780.781.20.110.110.390.390.78

Intermediate circuit voltage

Mains connection voltage x 1.41 V DC

Brake chopper/resistor

Type

HCS01.1E-W0003-A-02HCS01.1E-W0006-A-02HCS01.1E-W0009-A-02HCS01.1E-W0013-A-02HCS01.1E-W0018-A-02HCS01.1E-W0005-A-03HCS01.1E-W0008-A-03HCS01.1E-W0018-A-03HCS01.1E-W0028-A-03HCS01.1E-W0054-A-03

Braking energy consumption

kWs

0.40.40.40.430.80.82.25313

Continuous braking power

kW

0.020.020.030.030.150.020.030.050.150.5

Maximum braking power

kW

1.681.681.6825.82.24447.210.625.8

Control voltage

Type

HCS01.1E-W0003-A-02HCS01.1E-W0006-A-02HCS01.1E-W0009-A-02HCS01.1E-W0013-A-02HCS01.1E-W0018-A-02HCS01.1E-W0005-A-03HCS01.1E-W0008-A-03HCS01.1E-W0018-A-03HCS01.1E-W0028-A-03HCS01.1E-W0054-A-03

Control voltage, external

24 V ± 5 %
-

Power consumption without control unit and motor brake

W

27272828342728343445
  • 0.15 kW ... 14 kW power range
  • 3.3 A ... 54 A maximum current
  • 110 V ... 500 V direct power supply
  • High overload capacity
  • Compact design for single-axis applications
견적문의 목록