Compact Converter - IndraDrive Cs HCS03
The IndraDrive C (HCS03) converters cover the upper kW range of the power range. They come with a control unit slot that has various interfaces for connecting to the automation environment, for encoder systems, safety technology, and additional digital and analog signals, etc.
명판 사진 한 장이면 견적 문의를 시작할 수 있습니다. 모델명을 몰라도 됩니다.
특징
General data
Type | HCS03.1E-W0070 | HCS03.1E-W0100 | HCS03.1E-W0150 | HCS03.1E-W0210 | HCS03.1E-W0280 | HCS03.1E-W0350 |
|---|---|---|---|---|---|---|
EMC (electro-magnetic compatibility) | EN 61800-3 | |||||
Type of cooling | Forced ventilation |
Performance data
Type | HCS03.1E-W0070 | HCS03.1E-W0100 | HCS03.1E-W0150 | HCS03.1E-W0210 | HCS03.1E-W0280 | HCS03.1E-W0350 | |
|---|---|---|---|---|---|---|---|
Continuous current | A | 45 | 75 | 95 | 145 | 165 | 200 |
Maximum current | A | 70 | 100 | 150 | 210 | 280 | 350 |
Motor nominal capacity, typical | kW | 22 | 37 | 45 | 75 | - | - |
Mains connection voltage | 3 AC | 400 ... 500 V | |||||
Tolerance | % | + 10 - 15 | + 10 - 15 | + 10 - 15 | + 10 - 15 | + 10 - 15 | + 10 - 15 |
Frequency | 50 ... 60 Hz | 50 ... 60 Hz | 50 ... 60 Hz | 50 ... 60 Hz | 50 ... 60 Hz | 50 ... 60 Hz | |
Frequency tolerance | Hz | ± 2 | ± 2 | ± 2 | ± 2 | ± 2 | ± 2 |
Continuous current mains input | A | 50 | 80 | 106 | 146 | 176 | 201 |
Power dependency from the supply voltage | ULN < 400 V | 1% power reduction per 4 V | |||||
ULN > 400 V | 1 % power gain per 5 V | ||||||
Network contactor | External |
Intermediate circuit
Type | HCS03.1E-W0070 | HCS03.1E-W0100 | HCS03.1E-W0150 | HCS03.1E-W0210 | HCS03.1E-W0280 | HCS03.1E-W0350 | ||
|---|---|---|---|---|---|---|---|---|
Continuous power with choke | kW | 25 | 43 | 56 | 85 | 100 | 120 | |
Max. power with choke | kW | 40 | 59 | 89 | 124 | 170 | 210 | |
Continuous power without choke | kW | 13 | 24 | 34 | 47 | 83 | 100 | |
Max. power without choke | kW | 20 | 33 | 54 | 68 | 146 | 175 | |
Switching frequency/max. output frequency | 4 kHz | 0 ... 400 Hz | 0 ... 400 Hz | 0 ... 400 Hz | 0 ... 400 Hz | 0 ... 400 Hz | 0 ... 400 Hz | |
8 kHz | 0 ... 800 Hz | 0 ... 800 Hz | 0 ... 800 Hz | 0 ... 800 Hz | 0 ... 800 Hz | 0 ... 800 Hz | ||
12 kHz | 0 ... 1200 Hz | 0 ... 1200 Hz | 0 ... 1200 Hz | 0 ... 1200 Hz | - | - | ||
16 kHz | 0 ... 1600 Hz | 0 ... 1600 Hz | 0 ... 1600 Hz | 0 ... 1600 Hz | - | - | ||
Output voltage | 3 x AC 0 ... 480 V | |||||||
Intermediate circuit capacity | mF | 0.94 | 1.44 | 1.88 | 4.7 | 6.8 | 6.8 | |
Intermediate circuit voltage | Mains connection voltage x 1.41 V DC | |||||||
Ability to combine converter/inverter | ● | ● | ● | ● | ● | ● |
Brake chopper/resistor
Type | HCS03.1E-W0070 | HCS03.1E-W0100 | HCS03.1E-W0150 | HCS03.1E-W0210 | HCS03.1E-W0280 | HCS03.1E-W0350 | |
|---|---|---|---|---|---|---|---|
Brake resistor | External | ||||||
Brake chopper | Internal | ||||||
Braking energy consumption | kWs | 42 | 63 | 97 | 137 | - | - |
Continuous braking power | kW | 13.2 | 18.9 | 25.2 | 42.6 | 42.6 | 42.6 |
Control voltage
Type | HCS03.1E-W0070 | HCS03.1E-W0100 | HCS03.1E-W0150 | HCS03.1E-W0210 | HCS03.1E-W0280 | HCS03.1E-W0350 | |
|---|---|---|---|---|---|---|---|
Control voltage, internal | 24 V | ||||||
Power consumption without control unit and motor brake | W | 22.5 | 25 | 25 | 30 | 30 | 30 |
Legend | |
|---|---|
● | Standard |
○ | Option |
▼ | In preparation |
용도
- 22 kW ... 110 kW power range
- 70 A ... 350 A maximum current
- 400 V ... 500 V direct power supply
- 1.5x overload capacity
- Compact design for single-axis applications