The HMV01 supply units generate a DC bus voltage from the supply voltage. They come in rectifier and rectifier/regeneration variants. Rectifier/regeneration variants can also feed regenerative energy back into the supply network, keeping the DC bus voltage at a constant level regardless of supply voltage. Depending on size, the supply units come with integrated components, such as network contactor, braking transistor or brake resistor. Air cooling is the only type of cooling available.
명판 사진 한 장이면 견적 문의를 시작할 수 있습니다. 모델명을 몰라도 됩니다.
특징
General data
Type | HMV01.1E-W0030 | HMV01.1E-W0075 | HMV01.1E-W0120 | HMV01.1R-W0018 | HMV01.1R-W0045 | HMV01.1R-W0065 | HMV01.1R-W0120 |
|---|---|---|---|---|---|---|---|
EMC (electro-magnetic compatibility) | EN 61800-3 | ||||||
Type of cooling | Forced ventilation |
Performance data
Type | HMV01.1E-W0030 | HMV01.1E-W0075 | HMV01.1E-W0120 | HMV01.1R-W0018 | HMV01.1R-W0045 | HMV01.1R-W0065 | HMV01.1R-W0120 | |
|---|---|---|---|---|---|---|---|---|
Input voltage | 3 x AC 380 ... 480 V | |||||||
Tolerance | % | ± 10 - | ± 10 - | ± 10 - | ± 10 - | ± 10 - | ± 10 - | ± 10 - |
Frequency | 50 ... 60 Hz | 50 ... 60 Hz | 50 ... 60 Hz | 50 ... 60 Hz | 50 ... 60 Hz | 50 ... 60 Hz | 50 ... 60 Hz | |
Frequency tolerance | Hz | ± 2 | ± 2 | ± 2 | ± 2 | ± 2 | ± 2 | ± 2 |
Continuous current mains input | A | 51 | 125 | 0 | 26 | 65 | 94 | 181 |
Power dependency from the supply voltage | ULN < 400 V | 1% power reduction per 4 V | ||||||
ULN > 400 V | 1 % power gain per 5 V | No power gain |
Intermediate circuit
Type | HMV01.1E-W0030 | HMV01.1E-W0075 | HMV01.1E-W0120 | HMV01.1R-W0018 | HMV01.1R-W0045 | HMV01.1R-W0065 | HMV01.1R-W0120 | |
|---|---|---|---|---|---|---|---|---|
Continuous power with choke | kW | 30 | 75 | 120 | 18 | 45 | 65 | 120 |
Max. power with choke | kW | 45 | 112.5 | 180 | 45 | 112 | 162 | 180 |
Continuous power without choke | kW | 18 | 45 | 72 | 0 | - | - | - |
Max. power without choke | kW | 45 | 112.5 | 180 | 0 | - | - | - |
Output voltage | 435 ... 710 V DC | 750 V DC | ||||||
Intermediate circuit capacity | mF | 1.41 | 3.76 | 5.64 | 0.705 | 1.88 | 2.82 | 4.95 |
Intermediate circuit voltage | Mains connection voltage x 1.41 V DC | 750 V, regulated |
Brake chopper/resistor
Type | HMV01.1E-W0030 | HMV01.1E-W0075 | HMV01.1E-W0120 | HMV01.1R-W0018 | HMV01.1R-W0045 | HMV01.1R-W0065 | HMV01.1R-W0120 | |
|---|---|---|---|---|---|---|---|---|
Brake resistor | Internal | External | ||||||
Braking energy consumption | kWs | 100 | 250 | 500 | 80 | 100 | 150 | - |
Continuous braking power | kW | 1.5 | 2 | 2.5 | 0.4 | 0.4 | 0.4 | - |
Maximum braking power | kW | 36 | 90 | 130 | 36 | 90 | 130 | - |
Control voltage
Type | HMV01.1E-W0030 | HMV01.1E-W0075 | HMV01.1E-W0120 | HMV01.1R-W0018 | HMV01.1R-W0045 | HMV01.1R-W0065 | HMV01.1R-W0120 | |
|---|---|---|---|---|---|---|---|---|
Control voltage, external | 24 V ± 5 % - | |||||||
Power consumption without control unit and motor brake | W | 25 | 30 | 55 | 31 | 41 | 108 | 224 1) |
| 1) | HAB fan unit included |
|---|
용도
- 18 kW ... 120 kW power range
- 380 V ... 480 V mains connection voltage
- Protection type IP20