The HMD01 double-axis inverters are powered by direct current and use it to generate two independently controlled AC output voltages of variable amplitude and frequency for operating two motors. They come with a control unit slot that has various interfaces for connecting to the automation environment, for encoder systems, safety technology, and additional digital and analog signals, etc. The firmware in the control unit controls both inverters independently and offers extensive additional functions. For multi-axis applications, the inverters are powered by the DC bus from HMV01 or HMU05 supply devices. It is also possible to power the inverters from the DC bus of an HCS converter for smaller axis packages and with an appropriate power reserve in the HCS.
명판 사진 한 장이면 견적 문의를 시작할 수 있습니다. 모델명을 몰라도 됩니다.
특징
General data
Type | HMD01.1N-W0012 | HMD01.1N-W0020 | HMD01.1N-W0036 |
|---|---|---|---|
EMC (electro-magnetic compatibility) | EN 61800-3 | ||
Type of cooling | Forced ventilation |
Performance data
Type | HMD01.1N-W0012 | HMD01.1N-W0020 | HMD01.1N-W0036 | |
|---|---|---|---|---|
Input voltage | 254 ... 750 V DC | |||
Continuous current | A | 6.9 | 10 | 20 |
Maximum current | A | 12 | 20 | 36 |
Motor nominal capacity, typical | kW | 3 | 4 | 7.5 |
Intermediate circuit
Type | HMD01.1N-W0012 | HMD01.1N-W0020 | HMD01.1N-W0036 | ||
|---|---|---|---|---|---|
Switching frequency/max. output frequency | 4 kHz | 0 ... 400 Hz | 0 ... 400 Hz | 0 ... 400 Hz | |
8 kHz | 0 ... 800 Hz | 0 ... 800 Hz | 0 ... 800 Hz | ||
Output voltage | 3 x AC 0 ... Mains connection voltage V | ||||
Intermediate circuit voltage | 254 ... 750 V DC |
Control voltage
Type | HMD01.1N-W0012 | HMD01.1N-W0020 | HMD01.1N-W0036 | |
|---|---|---|---|---|
Power consumption without control unit and motor brake | W | 17 | 17 | 11 |
용도
- 3 kW ... 7.5 kW power range
- 7 A ... 20 A continuous current
- 12 A ... 36 A maximum current
- 540 V ... 750 V DC line voltage
- Protection type IP20