Bosch RexrothInverters & servo drives

Modular converter - IndraDrive ML HMU05 - supply device/inverter

HMU05 universal inverters can be used both as a single-axis inverter for operating a motor and a rectifier/regeneration supply unit. They come with a control unit slot that has various interfaces for connecting to the automation environment, for encoder systems, safety technology, and additional digital and analog signals, etc. The use of the HMU05 is determined by the firmware in the control unit and, if necessary, mains connection components. Liquid cooling is the only type of cooling available.
When operated as a single-axis inverter, the HMU05 is powered by direct current and uses it to generate a controlled AC output voltage of variable amplitude and frequency for operating a motor. The firmware in the control unit controls the single-axis inverter and offers extensive additional functions. The inverters are powered by the DC bus from an HMU05 operated as a supply unit.
When used as a rectifier/regeneration supply unit, the HMU05 generates DC bus voltage from the supply voltage. This means it can also feed regenerative energy back into the supply network, keeping the DC bus voltage at a constant level regardless of supply voltage. The firmware in the control unit controls the supply unit and offers extensive additional functions.

One nameplate photo is enough to start a quote request. You do not need to know the model name.

Features

General data

Type

HMU05.1N-F0140-0350HMU05.1N-F0170-0430HMU05.1N-F0220-0510HMU05.1N-F0270-0660HMU05.1N-F0340-0820HMU05.1N-F0430-1040HMU05.1N-F0540-1300

Degree of contamination

2 (EN 50178)

Device protection type/connections

IP20/IP00 (IEC529)

Type of cooling

Liquid cooling

EMC (electro-magnetic compatibility)

EN 61800-3

Power dissipation in water

kW

2.1
0.4
2.5
0.5
3.5
0.75
4.5
1
4.5
1
5.5
1
7.5
1.2

Power data as power inverter (low overload capacity3) | high overload capacity4))

Type

HMU05.1N-F0140-0350HMU05.1N-F0170-0430HMU05.1N-F0220-0510HMU05.1N-F0270-0660HMU05.1N-F0340-0820HMU05.1N-F0430-1040HMU05.1N-F0540-1300

DC bus baseline power

144/120 kW173/144 kW216/173 kW270/216 kW339/270 kW430/339 kW535/430 kW

DC bus overload power

158/180 kW190/216 kW238/260 kW297/324 kW373/405 kW473/509 kW589/645 kW

Line input current (baseline power)

216/180 A260/216 A324/260 A405/324 A509/405 A645/509 A803/645 A

Continuous DC bus output

kW

145174219273342435540

Mains connection voltage

3 AC

3 x V AC 380 ... 500 (-15%/+10%)

Mains frequency

50/60 Hz (-5%/+5%)

DC bus voltage

Regulated, variable, 1.56 x UNetz or fixed 750 V

Power data as motor inverter (low overload capacity3) | high overload capacity4))

Type

HMU05.1N-F0140-0350HMU05.1N-F0170-0430HMU05.1N-F0220-0510HMU05.1N-F0270-0660HMU05.1N-F0340-0820HMU05.1N-F0430-1040HMU05.1N-F0540-1300

Typical motor output 1)

132/110 kW160/132 kW200/160 kW250/200 kW315/250 kW400/315 kW500/400 kW

Base-load current

251/209 A303/251 A388/303 A485/388 A610/485 A763/610 A992/763 A

Overload current

276/314 A333/377 A427/454 A533/582 A671/727 A839/915 A1091/1144 A

Continuous current

A

2543063924906167711002

Maximum current

A

35742751566082510371297

Nominal switching frequency

kHz

4444222

Switching frequency/max. output frequency

2 kHz

0 ... 200 Hz0 ... 200 Hz0 ... 200 Hz0 ... 200 Hz0 ... 200 Hz0 ... 200 Hz0 ... 200 Hz

4 kHz

0 ... 400 Hz0 ... 400 Hz0 ... 400 Hz0 ... 400 Hz0 ... 400 Hz0 ... 400 Hz0 ... 400 Hz

8 kHz

0 ... 800 Hz0 ... 800 Hz0 ... 800 Hz0 ... 800 Hz0 ... 800 Hz0 ... 800 Hz0 ... 800 Hz

Derating factor 2 to 4 kHz

----0.89 2)0.81 2)0.77 2)

Derating factor 4 to 8 kHz 2)

0.720.850.80.710.670.750.68
1)4-pin asynchronous motor, 400 V, 50 Hz
2)Related to continuous current
3)1.1x for 1 minute over 10 minutes
4)1.5x for 1 minute over 10 minutes

Other data

Type

HMU05.1N-F0140-0350HMU05.1N-F0170-0430HMU05.1N-F0220-0510HMU05.1N-F0270-0660HMU05.1N-F0340-0820HMU05.1N-F0430-1040HMU05.1N-F0540-1300

Parallel switching capable up to 8 units 1)

●●●●●●●

Derating of mains inverter in parallel

0.950.950.950.950.950.950.95

Derating of motor inverter in parallel

0.90.90.90.90.90.90.9

Intermediate circuit capacity

mF

4.954.956.68.259.913.216.5

Network contactor

External

Braking transistor/ resistor

External
1)Up to 4 kHz possible (8 kHz on request), only devices with the same performance

Control voltage data

Type

HMU05.1N-F0140-0350HMU05.1N-F0170-0430HMU05.1N-F0220-0510HMU05.1N-F0270-0660HMU05.1N-F0340-0820HMU05.1N-F0430-1040HMU05.1N-F0540-1300

Control voltage, external

24 V DC (±20%)
24 V DC (±5%) for power supply to the motor holding brake

Power consumption without control unit and motor brake

W

41485346485558

Continuous current without control unit and motor brake

A

1.722.21.922.32.4

Legend

●

Standard

○

Option

▼

In preparation

Applications

  • Universally usable as supply device or as single-axis inverter
  • 110 kW ... 4 MW power range
  • 380 V ... 690 V mains connection voltage
  • 540 V ... 1100 V DC line voltage
  • Rectifier and regeneration function (when used as supply unit)

Bosch Rexroth products

Call Ask about this product