Modular converter - IndraDrive ML HMU05 - supply device/inverter
HMU05 universal inverters can be used both as a single-axis inverter for operating a motor and a rectifier/regeneration supply unit. They come with a control unit slot that has various interfaces for connecting to the automation environment, for encoder systems, safety technology, and additional digital and analog signals, etc. The use of the HMU05 is determined by the firmware in the control unit and, if necessary, mains connection components. Liquid cooling is the only type of cooling available.
When operated as a single-axis inverter, the HMU05 is powered by direct current and uses it to generate a controlled AC output voltage of variable amplitude and frequency for operating a motor. The firmware in the control unit controls the single-axis inverter and offers extensive additional functions. The inverters are powered by the DC bus from an HMU05 operated as a supply unit.
When used as a rectifier/regeneration supply unit, the HMU05 generates DC bus voltage from the supply voltage. This means it can also feed regenerative energy back into the supply network, keeping the DC bus voltage at a constant level regardless of supply voltage. The firmware in the control unit controls the supply unit and offers extensive additional functions.
명판 사진 한 장이면 견적 문의를 시작할 수 있습니다. 모델명을 몰라도 됩니다.
특징
General data
Type | HMU05.1N-F0140-0350 | HMU05.1N-F0170-0430 | HMU05.1N-F0220-0510 | HMU05.1N-F0270-0660 | HMU05.1N-F0340-0820 | HMU05.1N-F0430-1040 | HMU05.1N-F0540-1300 | |
|---|---|---|---|---|---|---|---|---|
Degree of contamination | 2 (EN 50178) | |||||||
Device protection type/connections | IP20/IP00 (IEC529) | |||||||
Type of cooling | Liquid cooling | |||||||
EMC (electro-magnetic compatibility) | EN 61800-3 | |||||||
Power dissipation in water | kW | 2.1 0.4 | 2.5 0.5 | 3.5 0.75 | 4.5 1 | 4.5 1 | 5.5 1 | 7.5 1.2 |
Power data as power inverter (low overload capacity3) | high overload capacity4))
Type | HMU05.1N-F0140-0350 | HMU05.1N-F0170-0430 | HMU05.1N-F0220-0510 | HMU05.1N-F0270-0660 | HMU05.1N-F0340-0820 | HMU05.1N-F0430-1040 | HMU05.1N-F0540-1300 | |
|---|---|---|---|---|---|---|---|---|
DC bus baseline power | 144/120 kW | 173/144 kW | 216/173 kW | 270/216 kW | 339/270 kW | 430/339 kW | 535/430 kW | |
DC bus overload power | 158/180 kW | 190/216 kW | 238/260 kW | 297/324 kW | 373/405 kW | 473/509 kW | 589/645 kW | |
Line input current (baseline power) | 216/180 A | 260/216 A | 324/260 A | 405/324 A | 509/405 A | 645/509 A | 803/645 A | |
Continuous DC bus output | kW | 145 | 174 | 219 | 273 | 342 | 435 | 540 |
Mains connection voltage | 3 AC | 3 x V AC 380 ... 500 (-15%/+10%) | ||||||
Mains frequency | 50/60 Hz (-5%/+5%) | |||||||
DC bus voltage | Regulated, variable, 1.56 x UNetz or fixed 750 V |
Power data as motor inverter (low overload capacity3) | high overload capacity4))
Type | HMU05.1N-F0140-0350 | HMU05.1N-F0170-0430 | HMU05.1N-F0220-0510 | HMU05.1N-F0270-0660 | HMU05.1N-F0340-0820 | HMU05.1N-F0430-1040 | HMU05.1N-F0540-1300 | ||
|---|---|---|---|---|---|---|---|---|---|
Typical motor output 1) | 132/110 kW | 160/132 kW | 200/160 kW | 250/200 kW | 315/250 kW | 400/315 kW | 500/400 kW | ||
Base-load current | 251/209 A | 303/251 A | 388/303 A | 485/388 A | 610/485 A | 763/610 A | 992/763 A | ||
Overload current | 276/314 A | 333/377 A | 427/454 A | 533/582 A | 671/727 A | 839/915 A | 1091/1144 A | ||
Continuous current | A | 254 | 306 | 392 | 490 | 616 | 771 | 1002 | |
Maximum current | A | 357 | 427 | 515 | 660 | 825 | 1037 | 1297 | |
Nominal switching frequency | kHz | 4 | 4 | 4 | 4 | 2 | 2 | 2 | |
Switching frequency/max. output frequency | 2 kHz | 0 ... 200 Hz | 0 ... 200 Hz | 0 ... 200 Hz | 0 ... 200 Hz | 0 ... 200 Hz | 0 ... 200 Hz | 0 ... 200 Hz | |
4 kHz | 0 ... 400 Hz | 0 ... 400 Hz | 0 ... 400 Hz | 0 ... 400 Hz | 0 ... 400 Hz | 0 ... 400 Hz | 0 ... 400 Hz | ||
8 kHz | 0 ... 800 Hz | 0 ... 800 Hz | 0 ... 800 Hz | 0 ... 800 Hz | 0 ... 800 Hz | 0 ... 800 Hz | 0 ... 800 Hz | ||
Derating factor 2 to 4 kHz | - | - | - | - | 0.89 2) | 0.81 2) | 0.77 2) | ||
Derating factor 4 to 8 kHz 2) | 0.72 | 0.85 | 0.8 | 0.71 | 0.67 | 0.75 | 0.68 |
| 1) | 4-pin asynchronous motor, 400 V, 50 Hz |
|---|---|
| 2) | Related to continuous current |
| 3) | 1.1x for 1 minute over 10 minutes |
| 4) | 1.5x for 1 minute over 10 minutes |
Other data
Type | HMU05.1N-F0140-0350 | HMU05.1N-F0170-0430 | HMU05.1N-F0220-0510 | HMU05.1N-F0270-0660 | HMU05.1N-F0340-0820 | HMU05.1N-F0430-1040 | HMU05.1N-F0540-1300 | |
|---|---|---|---|---|---|---|---|---|
Parallel switching capable up to 8 units 1) | ● | ● | ● | ● | ● | ● | ● | |
Derating of mains inverter in parallel | 0.95 | 0.95 | 0.95 | 0.95 | 0.95 | 0.95 | 0.95 | |
Derating of motor inverter in parallel | 0.9 | 0.9 | 0.9 | 0.9 | 0.9 | 0.9 | 0.9 | |
Intermediate circuit capacity | mF | 4.95 | 4.95 | 6.6 | 8.25 | 9.9 | 13.2 | 16.5 |
Network contactor | External | |||||||
Braking transistor/ resistor | External |
| 1) | Up to 4 kHz possible (8 kHz on request), only devices with the same performance |
|---|
Control voltage data
Type | HMU05.1N-F0140-0350 | HMU05.1N-F0170-0430 | HMU05.1N-F0220-0510 | HMU05.1N-F0270-0660 | HMU05.1N-F0340-0820 | HMU05.1N-F0430-1040 | HMU05.1N-F0540-1300 | |
|---|---|---|---|---|---|---|---|---|
Control voltage, external | 24 V DC (±20%) 24 V DC (±5%) for power supply to the motor holding brake | |||||||
Power consumption without control unit and motor brake | W | 41 | 48 | 53 | 46 | 48 | 55 | 58 |
Continuous current without control unit and motor brake | A | 1.7 | 2 | 2.2 | 1.9 | 2 | 2.3 | 2.4 |
Legend | |
|---|---|
● | Standard |
○ | Option |
▼ | In preparation |
용도
- Universally usable as supply device or as single-axis inverter
- 110 kW ... 4 MW power range
- 380 V ... 690 V mains connection voltage
- 540 V ... 1100 V DC line voltage
- Rectifier and regeneration function (when used as supply unit)